Errata

Publications

Conference Papers

VCBM2010
Heckel, F; Konrad, O.; Peitgen, H.-O.
Fast and Smooth Interactive Segmentation of Medical Images Using Variational Interpolation
Proceedings of Eurographics Workshop on Visual Computing for Biology and Medicine, 2010, pp. 9-16 © EG
[doi:10.2312/VCBM/VCBM10/009-016]

  • Equation 8:
    The cosine of the angle between the vectors is needed for computing the weight.

SPIE2010
Heckel, F; Dicken, V.; Bostel, T.; Fabel, M.; Kießling, A.; Peitgen, H.-O.
Partial volume correction for volume estimation of liver metastases and lymph nodes in CT scans using spatial subdivision
Proceedings of SPIE Medical Imaging: Image Processing, 2010, 7623(1), pp. 76230T_1-11 © SPIE
[doi:10.1117/12.844200]

  • Table 2:
    The results are wrong due to sign errors for some of the relative differences. The correct results are:
    Size Number of lesions Voxel-count Corrected
    <2ml 33 16.0 (33.5) 6.5 (19.4)
    2-10ml 62 9.2 (16.2) 4.4 (9.2)
    >10ml 37 0.8 (11.7) 0.8 (10.7)
    All 132 8.5 (21.6) 3.9 (12.9)
    Nevertheless, the conclusion given in the paper holds true.

    This erratum has already been corrected in the copy of the paper that is available via this website and via the SPIE Digital Library.

SPIE2009
Heckel, F; Moltz, J. H.; Bornemann, L; Dicken, V.; Bauknecht, H.-C.; Fabel, M.; Hittinger, M.; Kießling, A.; Meier, S.; Püsken, M.; Peitgen, H.-O.
3D contour based local manual correction of tumor segmentations in CT scans
Proceedings of SPIE Medical Imaging: Image Processing, 2009, 7259(1), pp. 72593L_1-9 © SPIE
[doi:10.1117/12.812248]

  • Equation 6 and 7:
    Both the vector l(p,q) and the vector d(p) need to be normalized.